Home/Applications

Applications & Technical Solutions

Vastin valves specified for the most demanding fluids and operating conditions in industry: ammonia, steam and thermal oil.

RefrigerationHeatingSteamThermal OilAmmonia NH₃

The right valve for every fluid. No margin for error.

Each industrial application has its own pressure, temperature and chemical compatibility requirements. Vastin specifies and supplies valves with the correct materials, seals and pressure ratings for each system — ensuring tightness, operational safety and long service life.

Application Areas

Three technical areas. Hundreds of applications.

Industrial refrigeration systems operate with highly aggressive fluids — ammonia (NH₃) and other refrigerants. These fluids require valves with careful selection of body and seal materials. Vastin supplies shut-off valves, solenoids and check valves specifically selected for each type of refrigerant fluid.

Recommended valves

Shut-Off Valves for Ammonia (AO / PO Series)
Check Valves for Ammonia (RTR / AOVR / AOCVR)
Expansion Valves (AR / ARC / PR / PRC)
Filters for Ammonia (FIL-A / FIL-Y)
Safety Relief Valves (VASEGS / VASEGD)
View full catalog

Operational safety

Safe handling of Vastin valves

Industrial valves operating with pressurized fluids, toxic refrigerants or high-temperature steam require specific installation, operation and maintenance procedures. Following correct procedures is essential for plant and personnel safety.

ISO
9001:2015

Processes externally audited by SGS since 2012

Installation per flow direction

Every Vastin valve is marked with the flow arrow on the body. Installation in the wrong direction compromises the seal and can cause irreversible mechanical damage to the disc.

Controlled tightening torque

Packings and flanges must be tightened in a cross (X) pattern, progressively, respecting the specified torque. Over-tightening deforms the body; under-tightening causes leakage.

Slow operation — no water hammer

Opening and closing valves slowly prevents water hammer, especially in steam and hot water systems. Sudden maneuvers damage pipelines and downstream equipment.

Material compatibility verified

Before specifying, confirm with engineering the compatibility of the body and seal with the process fluid.

Periodic seal and packing inspection

Packings and O-rings should be inspected at least annually and preventively replaced. Ammonia or steam leaks are health and installation integrity risks.

Documentation and traceability

Each Vastin valve is delivered with quality documentation traceable to the serial number. Keep material and test certificates — they are required in audits and regulatory inspections.