Systems
See Vastin valves operating in real industrial systems — from the ammonia cycle to defrost, steam and thermal oil. Official, interactive technical diagrams.
Each system has its own fluid, pressure and operating-sequence requirements. Explore Vastin's official diagrams and see exactly which valve acts at each point — click to go straight to the product.
Industrial Refrigeration · NH₃
Defrost Manifold
The same Vastin valve manifold operating in each mode of the ammonia cycle. Pick a mode and see which flow — liquid, suction or hot gas — is active in that operation.
Valves in this diagram
Click to view the product
PO — PO Shut-off Valve

VRSOL — VRSOL Solenoid Valve

FIL-Y — FIL-Y Filter

PODG — PODG Defrost Valve

POCAL — POCAL Pressure Regulating Valve

PM+MAN — PM-10 Gauge Valve

PR — PR Expansion Valve

POC — POC Shut-off Valve

PRC — PRC Expansion Valve

RET — RET Check Valve
In Refrigeration I, 5 of the panel's commanded valves are closed — they are what reroutes the flow, not the piping.
Official Vastin technical diagram. Each valve is identified by its code (PO, POCAL, PR, FIL-Y…).
Vastin level float as a float tree
In a liquid separator vessel the floats are stacked in a column — each one switches at its own height as the liquid rises. Drag the level and watch the sequence: submerged floats signal liquid, and the top one triggers the high-high level alarm.
Valves in this diagram
Click to view the product
LS — VTB-LED Magnetic Liquid Level Float with Exclusive Illuminated Indicator
Operating level: the lower floats sense liquid while the upper ones stay dry — the separator's normal working band.
Based on Vastin's official application diagram. Click a float to view the product.
POCAL pressure regulator — three applications
The same POCAL serves very different arrangements: pumped, thermosiphon, or on the ammonia pump's return. In all of them its job is the same — hold pressure on the vessel side and send the surplus back to the separator. Switch applications and watch the circuit rearrange.
Valves in this diagram
Click to view the product
POCAL — POCAL Pressure Regulating Valve
Forced recirculation: the pump feeds the exchanger and the POCAL regulates pressure on the return to the vessel, keeping the exchanger flooded.
Based on Vastin's three official application diagrams. Click the valve to view the product.
Vastin valves on an oil separator vessel
An oil separator packs several nozzles into a small space, and each one calls for a different valve. Select a point on the vessel to see what goes there and why.
Dual safety valve at the top of the vessel: protects against overpressure with two bodies and a transfer valve, allowing one side to be serviced without taking the vessel out of operation.
View product →Valves in this diagram
Click to view the product
VASEGD — VASEGD Safety Relief Valve

AO — AO Shut-off Valve

AOHA — AOHA Shut-off Valve

PM-10 — PM-10 Gauge Valve

VDO — VDO Drain Valve
Based on Vastin's official application diagram.
Heating & Steam
Vastin valves in a steam system
The heat exchanger warms the process using hot water. The 3-way globe valve modulates that flow in real time: the transmitter (TT) reads process temperature, the controller (TIC) compares it against the setpoint and drives the valve (TCV), which blends hot water and return to hold the temperature steady.
Valves in this diagram
Click to view the product
TCV · V3V — 3-Way Pneumatic/Electropneumatic Globe Valve
Process well below setpoint: the TCV opens the exchanger port fully and closes the bypass — all hot water goes through the exchanger.
Based on Vastin's official application diagram. Click the valve to view the product.
Vastin valves in a thermal oil system
Closed loop: the pump recirculates oil through the heater and delivers it to the point of use. The check valve protects the pump against backflow, the shut-off valve isolates the hot line for maintenance, and the regulating valve trims flow at the consumer. The atmospheric expansion tank absorbs the oil's thermal expansion — its leg has no defined flow direction, which is why it isn't animated.
Valves in this diagram
Click to view the product
RTY — RTY Check Valve

VO — VO Shut-off Valve

VOR — VOR Regulating Valve
Normal duty: the pump recirculates oil through the heater and delivers it to the point of use, with all three valves open.
Based on Vastin's official application diagram. Click the valves to view each product.
Need to spec valves for your system?
Our engineering helps size every point of the circuit.